烽火10GEPON OLT 命令行故障处理 下载本文

烽火10GEPON OLT 命令行故障处理

目录

一、E8-C/FTTX(单用户故障) ...................................................................................................... 2

1.根据LOID反查用户接入信息(PON口和ONT ID) ......................................................... 2 2.查终端在线情况 .................................................................................................................... 2 3.查看ONU数据配置 .............................................................................................................. 2 4.用户ITV组播配置 ................................................................................................................ 3 5.重启onu以及关闭onu命令 ............................................................................................... 3 6.查看ONU上线离线时间 ...................................................................................................... 3 7.学习MAC(分按PON口,按ONU ,按具体ONU业务VLAN) ................................... 3 8.核对光路(开关PON口) .................................................................................................. 5 9.ONU收发光功率(单ONU和PON口下所有用户) ........................................................ 5

9.1、ONU收发光功率 ..................................................................................................... 5 9.2查看PON口光模块参数 ........................................................................................... 6 10.流氓onu定位命令 ............................................................................................................. 7 11.查看未授权ONU ................................................................................................................. 7 12.查看onu线路质量(是否有误码) ................................................................................. 7 13.查看onu下是否环路 (能否自动下线)........................................................................ 9 14.onu历史告警查看命令 ...................................................................................................... 9 二、OLT(设备和多用户故障) ..................................................................................................... 9

1.查看所有板卡,以及板卡型号,状态 ................................................................................ 9 2.重启板卡命令 ...................................................................................................................... 10 3.板卡在线时间以及板卡CPU利用率 ................................................................................. 10 4.复位PON口命令,查看PON口在线情况(历史离线) ............................................... 11 5.上行端口状态和收发光功率 .............................................................................................. 11 6.上行口误码 .......................................................................................................................... 12 7.上行口配置查看和修改方法(VLAN,双工,LACP等) ................................................ 12

7.1、查看上行口状态 .................................................................................................... 12 7.2、查看上联口LCAP报文统计 .................................................................................. 13 7.3、查看LCAP聚合组信息 .......................................................................................... 14 7.4、查看管理VLAN ...................................................................................................... 14 7.5、添加管理VLAN ...................................................................................................... 15 7.6、查看局端VLAN ...................................................................................................... 15 7.7、局端VLAN添加 ..................................................................................................... 15 7.8、修改上行口 ............................................................................................................ 16 8.组播全局配置(组播IP、组播代理、OPTION 82等) ................................................... 16 9.告警日志(板卡、端口、环路告警等) .......................................................................... 17

一、E8-C/FTTX(单用户故障)

1.根据LOID反查用户接入信息(PON口和ONT ID)

Admin\\onu# show onu log-id 40CDAEC0BEC1D722

ONU: 1-2-8 OnuType: OTHER2 (16) phy-id: d45f25edb696 log-id: 40CDAEC0BEC1D722 log-pwd: password: Auth-Status: Authed Auth-Type: Loid Admin\\onu#

2.查终端在线情况

Admin\\server# telnet solt X

XG8A\\onu# show auth ponno X

查看PON口ONU在线情况

XG8A\\onu# show auth ponno 2

NUM MAC CONFIG-TYPE ONU-NO ONU-STATE ---------------------------------------------------------------

1 d45f25eec20e OTH_ONU_2 1 SHUTDOWN

2 d45f25ee3e6e OTH_ONU_2 2 SHUTDOWN 3 d45f25eeb686 OTH_ONU_2 3 ONLINE 4 d45f25eedc7e OTH_ONU_2 4 ONLINE 5 c40938c087c8 OTH_ONU_2 5 ONLINE

3.查看ONU数据配置(只能针对烽火自有A类型、B类型ONU)

Admin\\onu\\lan# show onufe_service slot 1 pon 1 onu 2

NO. SL/LI/ONU PORT ID TYPE MODE CVID COS TPID TVID COS TPID SVI

D COS TPID PVID COS

1 1 /1 /2 1 1 unica tag 55 0 33024 null null null nul l null null null null 2 1 /1 /2 1 2 unica tran 43 5 33024 null null null nul l null null null null 3 1 /1 /2 1 3 unica tran 42 6 33024 null null null nul l null null null null Admin\\onu\\lan#

4.用户ITV组播配置(只能针对烽火自有A类型、B类型ONU)

配置ONU1的端口4的组播内层VLAN为40,内层COS为5,TPID为33024,

外层

VLAN为40,外层COS为5,TPID为33024。该ONU位于槽位12的PON口1下。

Admin\\onu\\lan#set epon slot 12 pon 1 onu 1 port 4 cvid 40 ccos 5 ctpid 33024 svid 40 scos 5 stpid 33024 Admin\\onu\\lan#

5.重启onu命令

对槽位1的PON口1下的ONU1到ONU10进行复位重启。

Admin\\maintenance#reboot slot 1 pon 1 onulist 1~10 Admin\\maintenance#

6.查看ONU上线离线时间

Admin\\onu# show onu_last_on_and_off_time slot 2 pon 1 onu 1

SLOT PON ONU LAST_OFF_TIME LAST_ON_TIME

2 1 1 Last Off Time = 2017-05-22 12:46:20,Last On Time = 2017-05-22 12:48:04.

Admin\\onu#

7.学习MAC(分按PON口,按ONU ,按具体ONU业务VLAN)

查看PON口MAC地址表

1、查看所有槽位所有PON口,查询某槽位所有PON口MAC地址 Admin#cd card

Admin\\card# show pon-mac all //查询所有槽位mac地址表

Admin\\card# show pon-mac slot //查询具体槽位号mac地址表

Admin\\card# show pon-mac all

----------------- MAINBOARD MAC LIST ------------- //主控盘MAC地址表

SLOT PORT ONU MAC VLAN --------------------------------------------------

--- trunk 1 --- 0c:a4:02:9a:79:4a 303 --- trunk 1 --- 00:0f:e2:07:f2:e0 4088 --- trunk 1 --- 0c:a4:02:9a:79:4a 50 --- trunk 1 --- 0c:a4:02:9a:79:4a 40 ----- mainboard MAC, item=4 -----

------------------- PON MAC LIST ----------------- // PON口MAC地址表 SLOT PON ONU MAC VLAN --------------------------------------------------

1 1 1 D4:5F:25:EE:E7:91 1901 1 1 1 D4:5F:25:EE:E7:92 301 1 1 1 D4:5F:25:EE:E7:91 301 1 1 1 D4:5F:25:EE:E7:95 2701

----- slot 1 pon 1 MAC, item=4 ----- // 1槽位1pon口mac地址表

1 3 1 D4:5F:25:EE:CE:4A 1903 1 3 1 D4:5F:25:EE:CE:4A 0 1 3 1 D4:5F:25:EE:CE:4B 303 1 3 1 D4:5F:25:EE:CE:4E 2703 ----- slot 1 pon 3 MAC, item=4 ----- //1槽位3PON口mac地址表

Admin\\card#

Admin\\card# show pon-mac slot 1 //查询1槽位mac地址表

------------------- PON MAC LIST -----------------

SLOT PON ONU MAC VLAN --------------------------------------------------

1 1 1 D4:5F:25:EE:E7:91 1901 1 1 1 D4:5F:25:EE:E7:92 301 1 1 1 D4:5F:25:EE:E7:91 301 1 1 1 D4:5F:25:EE:E7:95 2701

----- slot 1 pon 1 MAC, item=4 ----- // 1槽位1pon口mac地址表

1 3 1 D4:5F:25:EE:CE:4A 1903 1 3 1 D4:5F:25:EE:CE:4A 0 1 3 1 D4:5F:25:EE:CE:4B 303 1 3 1 D4:5F:25:EE:CE:4E 2703

----- slot 1 pon 3 MAC, item=4 ----- //1槽位3PON口mac地址表