megaraid硬RAID卡命令管理手册

二、 下载、安装 MegCli 下载地址:wget

http://img.aikaiyuan.com/2014/12/ibm_utl_sraidmr_megacli-8.00.48_linux_32-64.zip

#unzip ibm_utl_sraidmr_megacli-8.00.48_linux_32-64.zip #cd linux

#rpm -ivh Lib_Utils-1.00-09.noarch.rpm MegaCli-8.00.48-1.i386.rpm

#rpm -ivh MegaCli-8.00.48-1.i386.rpm

#故障硬盘修复(添加新硬盘或阵列)

#-PDMakeGood是改变状态由Unconfigured bad变成Unconfigured good

#-PhysDrv[252:2] 是硬盘信息[]内第一个数字是Enclosure Device ID,第二个数字是Slot Number #-a0 是Adapter #0

1./opt/MegaRAID/MegaCli/MegaCli64 -PDMakeGood -PhysDrv[252:2] -a0 #硬盘变为Unconfigured good之后加入阵列

2./opt/MegaRAID/MegaCli/MegaCli64 -LDRecon -Start -r5 -Add -PhysDrv[252:2] -L0 -a0 3.等待重建,大约需要2小时

Reconstruction : Completed 0%, Taken 1 min.

使用/opt/MegaRAID/MegaCli/MegaCli64命令会在当前目录生成日志文件可以加上 -NoLog参数取消日志

三 使用命令及参数

命令使用:

#/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL 查raid级别 #/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL 查raid卡信息 #/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL 查看硬盘信息 #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll 查看电池信息

#/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL 查看raid卡日志

#/opt/MegaRAID/MegaCli/MegaCli64 -adpCount 【显示适配器个数】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL 【显示适配器时间】 #/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aAll 【显示所有适配器信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll 【显示所有的物理信息】 #/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】

#/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】

3.磁带状态的变化,从拔盘,到插盘的过程中。 Device |Normal|Damage|Rebuild|Normal

Virtual Drive |Optimal|Degraded|Degraded|Optimal

Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online 4.查看磁盘缓存策略

#/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -L0 -a0 or

#/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -L1 -a0 or

#/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -LALL -a0 ro

#/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -LALL -aALL ro

#/opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -DskCache -LALL -aALL 5.设置磁盘缓存策略 缓存策略解释:

WT (Write through WB (Write back)

NORA (No read ahead) RA (Read ahead)

ADRA (Adaptive read ahead) Cached Direct 例子:

#/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0 or

#/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -Cached|-Direct -L0 -a0 or

enable / disable disk cache

#/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -EnDskCache|-DisDskCache -L0 -a0

6.创建一个 raid5 阵列,由物理盘 2,3,4 构成,该阵列的热备盘是物理盘 5 #/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -Hsp[1:5] -a0

7.创建阵列,不指定热备

#/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -a0

8.删除阵列

#/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdDel -L1 -a0 9.在线添加磁盘

#/opt/MegaRAID/MegaCli/MegaCli64 -LDRecon -Start -r5 -Add -PhysDrv[1:4] -L1 -a0

10.阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。 #/opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ShowProg -LALL -aALL 或者以动态可视化文字界面显示

#/opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ProgDsply -LALL -aALL 11.查看阵列后台初始化进度

#/opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ShowProg -LALL -aALL 或者以动态可视化文字界面显示

#/opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ProgDsply -LALL -aALL 12.指定第 5 块盘作为全局热备

#/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0 13.指定为某个阵列的专用热备

#/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0 14.删除全局热备

#/opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Rmv -PhysDrv[1:5] -a0 15.将某块物理盘下线/上线

#/opt/MegaRAID/MegaCli/MegaCli64 -PDOffline -PhysDrv [1:4] -a0 #/opt/MegaRAID/MegaCli/MegaCli64 -PDOnline -PhysDrv [1:4] -a0 16.查看物理磁盘重建进度

#/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -PhysDrv [1:5] -a0 或者以动态可视化文字界面显示

#/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ProgDsply -PhysDrv [1:5] -a0

磁带状态的变化,从拔盘,到插盘的过程中: Device |Normal|Damage|Rebuild|Normal

Virtual Drive |Optimal|Degraded|Degraded|Optimal

Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online 1、 查看RAID级别

联系客服:779662525#qq.com(#替换为@) 苏ICP备20003344号-4