慧荣量产工具使用方法

SM32X ? There are two modes:

? Mode-A: The Public/Security mode, just one disk display in the same

time. ? Mode-C: The Public+Public/Security mode, there are two disks display in

the same time. The second disk is identical to mode-A.

? Server Generating SN support

? It needs the socket server to communicate with our MPTool. Just setting the

IP address and Port number, out MPTool will negotiate with the server during production.

? Enable Floppy Support

? Setting the one disk become floppy, it also support floppy format to FAT12

and preload functions. ? COM Communication Settings

? Setting the COM port number which connected to「Auto Handler」and

Enable/Disable the COM port function.

? Log file settings:

? Setup the format of log file and customize information. ? Enable Unique Serial Number:

? If enable this function, MPTool will retrieve the serial number from this ini file

only, although used the different INI files.

Version : 4.2 Confidential

- 16 - SM32X

Fig. 14 The Extra Setting Dialog

? Debug Button:

It’s for internal debugging using.

? Read CID:

Press the「Button」or 「row item」of mapped USB hub port, the information for device plugged in this port will be presented in Fig. 15. All fields are defined in Table 2.

Version : 4.2 Confidential

- 17 - SM32X

Fig. 15 The related information of CID. Table 2 The field Descriptions of CID .

Field VID PID Serial Vendor Str Product Str Inquiry Now the device USB vid string Now the device USB pid string Description Now the device USB serial number Now the device USB vendor string Now the device USB product string Now the device SCSI inquiry string Version : 4.2 Confidential

- 18 - SM32X ISP version System CLK IC ver Bad Block FLASH DSP Version Save Info Card Mode Erase CID, ISP ? INI Setting

Now the device ISP version Now the controller clock setting ,only for 320 controller clock setting. Now the device controller hardware version Show after pretest , bad block information Show flash maker code 、device code、the 3rd and 4th Byte information. The SM340 related information. Save the FlashID、CID、WPRO、PAR、CardMode、InforBlock(s) and ISP information into file for RD debugging. It will display the all card mode of current plugged UFD. Erasing the current UFD’s CID and ISP. ISP Check sum Read back download isp check sum Save Badblock It will scan the fully disk to save the all badblock. Below item not show on setting UI , must modify「ini」file : (1) CUSTOMER (2) READCLK (3) WRITECLK (4) RESERVEZONE

The all field in「ini」file description in Table 3.

Table 3 The all field descriptions in the「INI」file.

Name SERIALMETHOD Bytes 1 Default Value 0 Descript 0: USB serial number is increase 1: USB seial number is 0 2: USB serial number no update USBMAXPOWER 1 0 0: USB Power define 100mA 1: USB Power define 200mA 2: USB Power define 300mA 3: USB Power define 400mA 4: USB Power define 500mA - 19 - Version : 4.2 Confidential

SM32X DISKTYPE DISKSIZE 1 1 1 0 0: USB-HDD 1: USB-ZIP 0: No Check DiskCapacity 1: 16M , 2: 32M , 3: 64M , 4: 128M 5: 256M , 6: 512M , 7: 1G , 8: 2G 9: 4G APPLICATION 1 1 0: Card Reader 1: Flash Disk 2: CardReader+FlashDisk USB Vendor ID USB Product ID USB Vendor String USB Product String USB Serial number begin USB Serial number end , when serial number count to the number , program will stop SCSI Inquiry Product String SCSI Inquiry Vendor String Disk Volume Label USB bcdDevice version number 0: Auto Select ISP file download 1: Force select a ISP file download IF DEFAULTISP equal 1 then download the ISP File Setting Pretest bad block range SLC must more than 20 , MLC must more than 44 For different customer Application used. Autorun Image file name. Reserve data zone , size= n*1024 sector 0: when format MBR offset 0x1BE=0

VID PID VENDORSTR PRODUCTSTRING SERIALBEGIN SERIALEND INQUIRYSTRING INQUIRYVENDOR DISKLABEL DID DEFAULTISP ISPFILE BADBLOCK CUSTOMER AUTORUNFILE RESERVEZONE BOOTTYPE Version : 4.2 4 4 20 20 20 20 16 8 32 4 1 256 1 1 256 1 1 090C 1000 1000 0 20 1 0 0 Confidential - 20 -