110kV~750kV架空输电线路设计

Q / GDW 179 — 2008

目 次

前言 ····························································································································· Ⅱ 1 范围 ·························································································································· 1 2 规范性引用文件 ··········································································································· 1 3 术语和符号 ················································································································· 1 4 总则 ·························································································································· 4 5 路径 ·························································································································· 4 6 气象条件 ···················································································································· 5 7 导线和地线 ················································································································· 6 8 绝缘子和金具 ·············································································································· 9 9 绝缘配合、防雷和接地 ································································································ 10 10 导线布置 ················································································································· 13 11 杆塔型式 ················································································································· 15 12 杆塔荷载及材料 ········································································································ 15 13 杆塔结构设计基本规定······························································································· 21 14 基础设计 ················································································································· 24 15 对地距离及交叉跨越 ·································································································· 25 16 环境保护 ················································································································· 30 17 劳动安全和工业卫生 ·································································································· 30 18 附属设施 ················································································································· 30 附录A 典型气象区 ········································································································ 31 附录B 高压架空线路污秽分级标准 ··················································································· 32 附录C 各种绝缘子的m1参考值 ······················································································· 33 附录D 使用悬垂绝缘子串的杆塔,水平线间距离与档距的关系 ·············································· 35 附录E 基础上拔土计算容重和上拔角 ················································································ 36 附录F 弱电线路等级 ····································································································· 37 附录G 公路等级 ··········································································································· 38 附录H 用词和用语说明 ·································································································· 39 参考文献 ······················································································································· 40 条文说明 ······················································································································· 41

I

Q / GDW 179 — 2008

前 言

随着我国国民经济和电网建设的不断发展,我国的高压交流输电技术得到了迅速发展,目前,我国电网的最高运行电压等级从500kV发展到750kV。电网建设以科学发展观为指导,充分利用高新技术和先进设备,在加强现有电网技术改造和升级方面取得了较大的成果。许多新技术、新工艺和新材料正在得到广泛运用和大力推广,成为电网设计和建设中的重要组成部分。为了规范设计,统一标准,确保工程安全和工程造价合理,编制本规定。

本规定编制的指导思想是:贯彻电力建设基本方针,依靠科技进步和技术创新,认真落实安全可靠、先进适用、经济合理、环境友好的原则,体现设计方案的经济性、合理性。

本规定编制的技术原则:遵照DL/T 5092—1999《110~500kV架空送电线路设计技术规程》和参照Q/GDW 102—2003《750kV架空送电线路设计暂行技术规定》中的原则,并充分吸收规程颁发以来电力行业标准化、信息化研究推广应用的成果,在总结和分析的基础上编制而成。

本规定根据国家对环境保护的法律、法规,增设了环境保护章节。

本规定根据国家法规对劳动安全和工业卫生的要求,设置了劳动安全和工业卫生章节。

本规定根据电网建设中新技术、新工艺、新材料的应用,在路径、导线和地线、绝缘子和金具、杆塔结构等章节,增加了相关的内容。

本规定则体现了“基建为生产服务”的理念,认真研究生产运行提出的问题,在安全、经济、合理的基础上提出了适当的条文规定。

本标准由国家电网公司科技部归口。

本规定主要编制单位:国家电网公司、中国电力工程顾问集团公司、华东电力设计院。 本规定参加编制单位:西北电力设计院。

本规定主要起草人:舒印彪、于刚、刘开俊、郭日彩、梁政平、吴建生、李勇伟、李喜来、葛旭波、张强、张卫东、张鹏飞、廖宗高、龚永光、李永双、黄伟中、薛春林、何江、叶鸿声、扬元春、魏顺炎、王勇、张芳杰、王虎长、朱永平、管顺清、孙波、张华。

II

Q / GDW 179 — 2008

110kV~750kV架空输电线路设计技术规定

1 范围

本规定规定了交流110kV~750kV架空输电线路的设计技术规定和要求,并提供了必要的数据和计算公式。适用于新建110kV、220kV、330kV、500kV和750kV交流输电线路设计,对已建线路的改造和扩建项目,可根据具体情况和运行经验参照本规定设计。 2 规范性引用文件

下列文件中的条款通过本标准的引用而成为本规定的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本规定,然而,鼓励根据本规定达成协议的各方研究是否可使用这些文件的最新版本。

GB 15707—1995 高压交流架空送电线无线电干扰限值 GB 700—1988 碳素结构钢

GB/T 1591—1994 低合金结构钢

GB 3098.1—2000 紧固件机械性能 螺栓、螺钉和螺柱 GB 3098.2—2000 紧固件机械性能 螺母

GB 50009—2001 建筑结构荷载规范(2006版) GB 1200—1988 镀锌钢绞线 GB 0017—2003 钢结构设计规范

GB 50010—2002 混凝土结构设计规范

GB 7349—2002 高压架空输电线、变电站无线电干扰测量方法 GB 3096—1993 城市区域环境噪声标准 GB 50007—2002 建筑地基基础设计规范

DL/T 5092—1999 110~500kV架空送电线路设计技术规程

DL/T 5217—2005 220~500kV紧凑型架空送电线路设计技术规定 DL/T 5154—2002 架空送电线路杆塔结构设计技术规定 DL/T 5919—2005 架空送电线路基础设计技术规定

DL/T 620—1997 交流电气装置的过电压保护和绝缘配合 DL/T 621—1997 交流电气装置的接地

DL/T 864—2004 标称电压高于1000V交流架空线路用复合绝缘子使用导则 DL409—1991 电业安全工作规程(电力线路部分)

Q/GDW 102—2003 750kV架空送电线路设计暂行技术规定

HJ/T24—1998 500kV超高压送变电工程电磁辐射环境影响评价技术规范 3 术语和符号

下列术语和符号适用于本规定。 3.1

术语

1