精品文档 Page 21: Memory setting of first frequency after power-off P049 Power down Setting range: 0 processing 0, under voltage fault, then lock-in; 1, under-voltage fault, auto-resetting after power recover, not to start; 2, slow down and stop working when nearly under-voltage. 3, reserved; 4, reserved; The motion setting of converter after power-off and power recover. P050 Reserved P051 Reserved P052 Reserved P053 Option of analog Setting range: 0 output 0, output frequency of analog output, 0-Highest frequency corresponding to 0-10V; 1, output current of analog output, 0-2times of rated current of converter corresponding to 0-10V; This function is used as remote monitoring to output frequency and output power of converter by connecting with a DC Voltmeter or other equipments between AFM and COM terminal. The highest output voltage of AFM terminal is 10V. P054 The corresponding output of the minimum analog quantity Setting range: 0.00-3.00V 0.0 Setting of signal strength of the terminal under minimum analog quantity (0Hz or 0A). 10.00 P055 The maximum Setting range: 5.00-20.00V analog quantity 精品文档 精品文档 Page22: The corresponding output Setting of signal strength of the terminal under maximum analog quantity (highest frequency or 2 times of rated current of converter). Attention: the parameter is used for revising the quantity of analog output, the actual highest output voltage of AFM terminal is 10V. 0 P056 Options of display Setting range: for starting up 0, frequency (H, F); 1, motor current (A); 2, busbar voltage (U); 3, output voltage (u); 4, approximately speed of machine=output frequency﹡ratio of RPM (r); 5, PID fixed variable (y); 6, PID feedback quantity (L); 7, attribute data (J); 8, factory text reserved (d); P057 Ratio of RPM Setting range: 0.01-100.00 30.00 The function is used for setting the ratio of display value of speed and working frequency, so as to enable the speed display value to keep consistent with the actual speed. Setting range: 0-5 respectively reflect to 3k, 5k, 7k, 9k, 30.00 11k, 13k The higher the carrier frequency is, the lower noise of the motor, the more interference of the battery, the hotter of the converter, the increasing of leakage current, and the decreasing of the efficiency. The lower the carrier frequency is, vice versa. P058 Carrier frequency P059 Setting of random Setting range: 0.0-1000.0Hz 0.0Hz frequency When the output frequency of converter≥the setting point, the converter may process signal output through multi function output terminal. 精品文档
精品文档
Page33: P125 Reserved P126 Attribute data Setting range: 0-65000 0 The attribute data of this parameter setting counter, the external counting pulse signal enable this parameter increase upward. Setting range: 0-65000 100 This function is used for prevalue setting of counter, when the attribute data is equal to present count, the system will be working based on P129. P127 Present count P128 Count till warning Setting range: 1-65000 90 This function is used for warn setting of counter, so as to prepare next step of working before counting reached. When counting reach to warning number, the system is able to output signal through terminal. P129 Count till option Setting range: of motion 0, output closing; 1, output on going; P130 Time unit procedure operating of 0: second; 1: minute; 2: hour 0 0 P131 First speed of 0-6553.0 operating time P132 Second speed of 0-6553.0 operating time P133 Third speed of 0-6553.0 operating time P134 Fourth speed of 0-6553.0 operating time 0 0 0 0 精品文档